Wolf Warming drawer Poradnik Użytkowania i Eksploatacji Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
Warming Drawer Use & Care 7
wolfappliance.com
Warming drawer control panel.
ON/OFF
control
LCD Display Preset
temperature
controls
Variable
temperature
controls
(UP and DOWN)
Automatic
shut-off timer
adjustment
(UP and DOWN)
Electronic Controls
T
he electronic touch control panel is hidden when the
warming drawer is closed. With the warming drawer open,
the controls can be accessed at the top of the drawer just
behind the drawer front.
PRESETS
Your warming drawer features four preset temperature
settings; PROOF, LOW, MED and HIGH. Using the
PRESETS eliminates the need to manually set the temper-
ature and time.
TO SET THE TEMPERATURE:
1) Touch POWER ON/OFF.
2) Touch one of the PRESETS; PROOF, LOW, MED or
HIGH or touch the TEMP UP or DOWN arrow pad.
Touch the UP arrow to increase the temperature and
the DOWN arrow to decrease the temperature. Two
seconds after selecting the temperature/time, the ON
indicator will illuminate as well as a beep indicating
that the unit is on.
IMPORTANT NOTE: One of the PRESETS or the TEMP UP
or DOWN arrow pad must be pressed within 20 seconds
of turning unit on, or the unit will automatically shut off.
PREHEAT
During preheat, the temperature read-out in the LCD
display alternates between the setpoint and the actual
temperature. The word ”Lo will appear in the LCD display
until the temperature reaches 85˚F (30˚C). The unit will
beep once to signal preheat is complete.
AUTOMATIC SHUT-OFF
Your Wolf warming drawer has a factory preset automatic
shut-off time of four hours. The time interval of the auto-
matic shut-off can be adjusted from one minute to 24
hours.
TO SET AUTOMATIC SHUT-OFF:
1) Warming drawer must be OFF.
2) Touch POWER ON/OFF.
3) Touch one of the PRESETS; PROOF, LOW, MED or
HIGH or touch the TEMP UP or DOWN arrow pad.
Touch the UP arrow to increase the temperature and
the DOWN arrow to decrease the temperature.
4) Touch and hold the TIMER UP arrow to increase the
shut-off time or the DOWN arrow to decrease the
shut-off time.
5) The word TIMER will illuminate and the automatic
shut-off time will appear in the LCD display.
Preset Temperature Settings
PROOF 85°F (30°C)
LOW 120°F (50°C)
MED 160°F (70°C)
HIGH 200°F (95°C)
Przeglądanie stron 6