Site Preparation 7
subzero.com
Electrical Requirements
T
he electrical supply should be located within the shaded
area shown in the illustrations. Follow the National
Electrical Code and local codes and ordinances when
installing the receptacle. A separate circuit, servicing only
this appliance is required.
IMPORTANT NOTE: It is critical that the electrical outlet be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket. It must be
flush with the back wall and positioned with the grounding
prong to the right of the thinner blades.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
13" (330)
1
/4" (6)
4
1
/2"
(
114
)
POSITION OUTLET WITH
GROUNDING PRONG
TO THE RIGHT
FLOOR
2
1
/2" (64)
FRONT VIEW
27" (686) models. 36" (914) models.
17
1
/2" (445)
4
1
/2"
(
114
)
POSITION OUTLET WITH
GROUNDING PRONG
TO THE RIGHT
FRONT VIEW
FLOOR
2
1
/2" (64)
1
/4" (6)
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician
t
o be sure that it is wired with the correct polarity.
Verify that the outlet is properly grounded.