wolfappliance.com
|
13
TROUBLESHOOTING
Troubleshooting
OPERATION
Rangetop does not operate.
• Verify power is on.
• Verify electrical power to unit and home circuit breaker
is on.
Erratic ame, poor ignition or no ignition.
• Verify burner caps are positioned properly.
• Clean burner and igniter properly.
• If water spilled over recently, let area dry completely.
Use hair dryer, if desired.
• If burner cap secures to burner head, verify it is tightly
fastened.
• Push in knob, then release. Verify knob springs back.
Charbroiler clicks continually.
• Verify knob is set fully at HI.
Griddle indicator light ashes.
• Turn knob off, then back on. Flame was lost and unit
entered safety lock-out mode.
Komentarze do niniejszej Instrukcji