Cooktop Low-Profile Hood Installation 11
wolfappliance.com/specs
Wall Hoods—Ducted Installation
F
it 6" (152) flexible metal ducting (not provided) to the air
vent of the hood and seal with duct tape. Refer to illus 5
below.
For exhaust hoods, turn the upper flue over so that the air
exhaust grid is in the lower section.
WIRING CONNECTIONS
Electrical connection at the hood:
1) Run Romex
®
wire from the service panel to the hood’s
electrical box marked “120 V AC input”.
2) Remove the cover from the electrical box and remove
one knockout as shown in illus 6.
3) Secure the Romex
®
wire to the electrical box through a
conduit connector. Use wire connectors or wire nuts
approved by UL or C/UL.
4) Make electrical connections at the hood. Connect
white to white, black to black and green to ground.
5) Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
FLEXIBLE
DUCTING
Illus 5. Illus 6.
WIRING
BOX
IN-LINE OR REMOTE BLOWER WIRING
Blower connection at the hood:
1) Run Romex
®
wire from the in-line or remote blower to
the hoods electrical box marked “motor connection”.
2) Remove the cover from the electrical box and remove
one knockout as shown in illus 7 below.
3) Secure the Romex
®
wire to the electrical box through a
conduit connector. Use wire connectors or wire nuts
approved by UL or C/UL.
4) Make electrical connections at the hood. Connect
white to red, black to black and green to ground.
5) Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
IMPORTANT NOTE: Refer to installation instructions
provided with the in-line or remote blower assembly for
additional mounting and wiring instructions.
ATTACH FLUE EXTENSION
Insert the flue extensions, setting them on the hood.
Extend the upper flue to the ceiling and secure with two
screws as shown in illus 8.
WIRING
BOX
Illus 7. Illus 8.
SCREWS
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Komentarze do niniejszej Instrukcji

Brak uwag

Raritan Computer Switch Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Computerzubehör Raritan Computer Switch.
Wir stellen 1 PDF-Handbücher Raritan Computer Switch zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Computerzubehör Raritan Computer

Modelle Dokumententyp
DKX416 Bedienungsanleitung   Raritan Computer DKX416 User Manual, 269 Seiten
DOMINION KSX II Bedienungsanleitung   Raritan Computer DOMINION KSX II User Manual, 362 Seiten
Paragon switch Bedienungsanleitung   Raritan Computer Paragon switch User Manual, 117 Seiten
DKSXII-V2.3.0-0D-E Bedienungsanleitung   Raritan Computer DKSXII-V2.3.0-0D-E User Manual [en] , 362 Seiten
UST-IP Bedienungsanleitung   Raritan Computer UST-IP User Manual [en] , 64 Seiten